FlashShield™ is to be bonded in accordance with the National Electrical Code NFPA 70 Article 250.104 in the same manner as the minimum requirements for rigid metal piping. However, installers must always adhere to any local requirements that may conflict with these instructions. Does flashing go over or under house wrap? tyvek over or under flashing.

Can Flash shield be buried?

Under concrete/asphalt slab, sleeved CSST must be buried in accordance with all local codes.

Where does CSST need to be bonded?

The CSST must be permanently bonded directly to the grounding electrode system of the electrical service of the home in which the CSST is installed.

Does gas piping need to be bonded?

Bonding is required to prevent a possible electric shock hazard for persons that may be in contact with the gas piping and other grounded metallic building components. A stock hazard can result if these systems are energized at different levels of electrical potential.

Can you bury Gastite FlashShield?

5. The Gastite/FlashShield flexible gas piping system may be joined to other fuel gas piping systems by using approved threaded pipe couplings at the interface. 6. Flexible gas piping must never be used as a grounding electrode or as the grounding path for appliances or the electrical systems.

Can TracPipe be ran outside?

The TracPipe is uv rated, so it can go outside.

How do I strip flash shield?

Cut: Place cut-end of FlashShield tubing into Side 1 of the stripping tool up to the tube stop. Close the stripping tool around tubing. Begin rotating the tool back and forth on the CSST (3 – 5, 200º twists) while applying pressure until the blades cut through all 3 jacket layers.

Why does CSST need to be bonded?

CSST needs to be bonded. If CSST is installed without being properly bonded to current standards, you have an increased risk for damage to the material from a nearby lightning strike. If CSST is damaged, it can leak gas and cause an explosion and/or a fire.

How much does it cost to bond CSST?

How Much Does It Cost? As with most electrical repairs the cost can vary significantly based on many factors, but a good rule of thumb would be between $150 – $500 for most single-family homes in Central Iowa.

Does black gas pipe need to be grounded?

3 Answers. According to National Electrical Code, the pipe has to be bonded. However, it can be bonded using the grounding conductor serving the equipment that uses the gas.

Should a natural gas line be grounded?

CSST Gas Lines Must Be Grounded Since 2009, US building codes have required CSST to be bonded and grounded for safety, but that was not required during the first 18 years. If you have CSST in your home and gas supply line work was done there since 1990, you need to be sure it is safe.

Does my boiler need earth bonding?

There is no requirement for bonding a boiler; it is earthed. Supplementary bonding is not required in a kitchen. However, this is a favourite with plumbers because they do not understand.

Is CSST a code?

Approved polyethylene pipe may be used in underground applications. CSST may be used if it is part of a system listed by an approved agency, “ … … HCD noted that both copper tubing and CSST had previously been approved in California under the 1998 California Mechanical Code.

Can Gas Tight be buried?

Copper Tubing Size Underground PE Tubing is designed, tested and certified for direct burial. No additional assembly equipment required for installation – just chamfer and push.

Can you run flexible gas line inside?

Flex connectors: Flexible connectors are permitted to connect appliances to the gas piping. There has to be a shut-off valve at the connection to the rigid piping. This valve has to be in the same room as the appliance. … Flexible connectors may not be permitted on gas furnaces, water heaters, space heaters, etc.

Can I use Csst underground?

The flexible systems of the Pro-Flex CSST gas line can be used underground when transported in a water-proof, non-metallic pipeline.

Are TracPipe fittings reusable?

They are designed to be used on original installation only. It’s unsafe for reuse if there’s additional handling and removal of the connector.

What is flash shield plus?

FlashShield+™ flexible gas piping delivers industry leading household fault current and lightning protection. It utilizes a metallic-shield within its protective jacket to handle hi-voltage risks associated with lightning strikes as well as dielectric jackets for lower voltage associated with household fault current.

How far can I run CSST gas line?

CSST is safe to run from your main to very gas appliance you have. I have seen and helped install this in new home builds, and redone gas lines. Now the connectors I’ve installed or only to be used at a maximum (in my area) of only 6ft.

Should my gas meter be grounded?

Grounding and Bonding is one of the more involved sections of the electrical code. Things like gas piping don’t get “grounded” they get “bonded.” The meter itself isn’t required to be grounded or bonded.

Does CSST gas pipe need to be grounded?

CSST flexible gas piping must be bonded to reduce the risk of damage due to a lightning strike on the home. The most common issue that home inspectors find is the CSST system is not being properly bonded.

Should a gas pipe be earthed?

2 Answers from MyBuilder Gas Engineers The main earth bonding for the gas pipe should be done after the gas meter in 10mm bonding and not more the 60cm or after 1st tee off. The cross bonding under the boiler should connect all pipework and be done in 4mm bonding.

Why do gas pipes need to be earthed?

Protective bonding reduces the risk of life-threatening electric shocks and electrical fires in your home. It’s typically needed in older buildings where gas and water pipes are made from metal rather than plastic.

Does black iron pipe need to be grounded?

Systems that are made up of black iron (steel) pipe are bonded to prevent electrical shock in case the pipe comes into contact with an electrical circuit. But, the newer yellow corrugated stainless steel tubing needs to also be grounded to prevent it from exploding if struck by lightning.

What needs earth bonding in a house?

2 Answers from MyBuilder Electricians These should connect to 1) water installation pipes 2) gas installation pipes 3) other installation pipework and ducting 4) central heating and air con systems 5) exposed metallic structural parts of the building.

Is supplementary bonding still required?

You may need supplementary bonding for rooms containing a bath or shower, except where all circuits in the room are RCD protected and the main bonding is up to the required standard.

What is earth bonding?

The earth creates a safe route for the current to flow instead of causing electric shock. The purpose of bonding is to reduce the risk of electric shock if you find yourself touching separate metallic parts when there is a fault somewhere within the electrical installation.

How often should CSST be supported?

Tubing shall be supported in a workmanlike manner with pipe straps, bands or hangers suitable for the size and weight of the tubing, at intervals not to exceed those shown in Table 4-3. The referenced table requires support every 4′ for 3/8″ pipe, every 6′ for 1/2″, and every 8′ for anything larger.

Can you use stainless steel pipe for natural gas?

A–Congratulations! You are now the proud owner of some wonderful corrugated stainless steel tubing. This material was approved for residential use in 1988 by the National Fuel Gas Code. It is an ingenious method of supplying natural gas to fireplaces, furnaces, stove tops, clothes dryers and any other gas appliance.

Can you reuse CSST fittings?

The fittings have been tested for long life while withstanding extreme heat and cold. Pro-Flex CSST fittings and components are reusable. Pro-Flex CSST and Flak Jacket™ Arc-Resistant CSST are annealed to give the pipe better flexibility without altering its strength.

Can I bury black iron gas pipe?

The black gas pipe can be buried underground. But it needs some protective layer to keep it away from rust. Black iron pipes don’t contain any protective coating on them.

Can gas piping run through a concrete slab?

Furthermore, in most jurisdictions, gas lines are not allowed to travel beneath the slab of the residence (sidewalks, patios, etc, are ok, but not under the garage or living spaces) unless installed in a gas-tight conduit, sealed at each end.

Can you bury Gastite pipe?

Yes, it can. Gastite® CSST is suitable for both internal and external installation allowing for direct burial.